Foundation Wall - Inside Application

Step 1
Between pours, apply Xypex Concentrate slurry to joint surfaces at the rate of 2.0 lb./sq. yd. (1.0 kg/m2).

Step 2
In sealing strip, apply one slurry coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd. (0.8 kg/m2) then fill slot to surface with Xypex Concentrate in Dry-Pac form.

Step 3
Apply one slurry coat of Xypex Concentrate to wall and slab interface as indicated at the rate of 1.5 lb./sq. yd. (0.8 kg/m2).

Where poor drainage conditions exist or high hydrostatic pressures are anticipated, also apply a coat of Xypex Modified to wall and slab surfaces at the rate of 1.25 to 1.5 lb./sq. yd. (0.65 to 0.8 kg/m2).

Note 1: Schematic diagram shows Xypex application details only and does not depict standard requirements for waterstops or expansion joint sealants.

Note 2: Schematic drawing shows Xypex Coating application. Specifier may consider the alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where applicable.

Refer to Standard Specifications for more information.